INSTRUMENTS WITH A DIGITAL SOUL

Promotions

AX-5002

Temperature meter; LCD 4 digits, with a backlit; Resol: 0.1°C

AX-7020

Analogue multimeter; Features: universal; V AC: 10/50/250/500V

AX-LCR42A

LCR meter; double LCD (19,999/1999), bargraph, with a backlit

AX-2040

AC digital clamp meter; LCD (4000), with a backlit; V DC: 4÷400V

AX-176

Digital multimeter; LCD (6600), with a backlit; 3x/s; True RMS

AX-T2090

Non-contact voltage and cable detector; LCD, bargraph

AX-CP-07-R

Clip-on probe; pincers type; 10A; red; Grip capac: max.4mm; 4mm

AX-B150

Inspection camera; Display: LCD 2,4" (320x240); Cam.res: 640x480

AX-3003P

Pwr sup.unit: programmable laboratory; Channels: 1; 0÷30VDC; 1mV

AX-CP-04-R

Clip-on probe; with puncturing point; 10A; red; 4mm

AXIOMET Catalogue

Download Catalogue
(ver. 6)
PDF (12,9 MB)

Product specifications
Type of meter:
AC/DC digital clamp meter
Max. diameter of measured cable:
23 mm
Kind of display used:
LCD 3,75 digit (3999), with a backlit
Sampling:
2x/s
DC current measuring range:
0,01...40/400A
Measuring instrument features:
  • automatic power-off
  • HOLD function
  • REL function
  • display zeroing function in DCA measurements
  • overflow indicator
  • contactless voltage detector
  • low battery indicator
DC current measuring accuracy:
±(2,5% + 6 digits)
AC current measuring range:
0,01...40/400A
Bandwidth for AC current measurements:
50Hz...400Hz
AC current measuring accuracy:
±(3% + 10 digits)
DC voltage measuring range:
0,1m...400m/4/40/400/600V
DC voltage measuring accuracy:
±(1,5% + 3 digits)
AC voltage measuring range:
0,1m...400m/4/40/400/600V
AC voltage measuring accuracy:
±(2% + 5 digits)
Bandwidth for AC voltage measurements:
50Hz...400Hz
Resistance measuring range:
0,1...400/4k/40k/400k/4M/40MΩ
Resistance measuring accuracy:
±(1% + 4 digits)
Capacitance measuring range:
0,1n...40n/400n/4µ/40µ/100µF
Capacitance measuring accuracy:
±(3% + 5 digits)
Frequency measuring range:
0,001...5/50/500/5k/50k/150kHz
Frequency measuring accuracy:
±(1,2% + 2 digits)
Temperature measuring range:
-50...760 °C
Temperature measurement accuracy:
±(3% + 5 digits)
Duty cycle factor:
0.5...99 %
Duty cycle factor measurement accuracy:
±(1,2% + 2 digits)
Continuity test:
acoustic signal for R<150Ω
Diode test:
0,3mA, 1,5V
Dimensions:
200 x 50 x 35 mm
Weight without batteries:
183 g
Power supply:
set without battery, 1 battery 9V
Standard equipment:
  • case
  • test leads
  • drop-like K-type temperature probe
Measurement:
frequency, AC voltage, DC voltage, capacitance, AC current, DC current, resistance, temperature, duty cycle
Conform to the norm:
EN61010 600V CAT III
Measuring unit:
°C, °F
Current measuring resolution:
10 mA
Additional information
Gross weight:
0.479 kg