INSTRUMENTS WITH A DIGITAL SOUL

Promotions

AX-2040

AC digital clamp meter; LCD (4000), with a backlit; V DC: 4÷400V

AX-B150

Inspection camera; Display: LCD 2,4" (320x240); Cam.res: 640x480

AX-CP-07-R

Clip-on probe; pincers type; 10A; red; Grip capac: max.4mm; 4mm

AX-CP-04-R

Clip-on probe; with puncturing point; 10A; red; 4mm

AX-3003P

Pwr sup.unit: programmable laboratory; Channels: 1; 0÷30VDC; 1mV

AX-5002

Temperature meter; LCD 4 digits, with a backlit; Resol: 0.1°C

AX-176

Digital multimeter; LCD (6600), with a backlit; 3x/s; True RMS

AX-7020

Analogue multimeter; Features: universal; V AC: 10/50/250/500V

AX-T2090

Non-contact voltage and cable detector; LCD, bargraph

AX-LCR42A

LCR meter; double LCD (19,999/1999), bargraph, with a backlit

AXIOMET Catalogue

Download Catalogue
(ver. 6)
PDF (12,9 MB)

In order for the meter to be safely used for measuring electrical installation outside a building, CAT IV safety requirements according to PN-EN61010 standard have to be fulfilled. AX-58xB AXIOMET digital multimeters have necessary certificates and can be bought at a very attractive price!

More
Product specifications
Type of meter:
digital multimeter
Measurement:
frequency, transistors' gain h<sub>FE</sub>, inductance, AC voltage, DC voltage, capacitance, AC current, DC current, resistance, temperature
Measuring instrument features:
  • automatic power-off
  • PEAK HOLD function
  • impact resistant holster
  • manual ranging
  • enhanced range of resistance measurement to 2000MΩ
  • universal
  • low battery indicator
Kind of display used:
LCD 3,5 digit 28mm
DC voltage measuring range:
0,1m...200m/2/20/200/1000V
DC voltage measuring accuracy:
±(0,5% + 3 digits)
AC voltage measuring range:
0,1m...200m/2/20/200/750V
AC voltage measuring accuracy:
±(0,8% + 5 digits)
Bandwidth for AC voltage measurements:
40Hz...400Hz (to 200V), 40Hz...100Hz (to 750V)
DC current measuring range:
1µ...2m/20m/200m/20A
DC current measuring accuracy:
±(0,8% + 3 digits)
AC current measuring range:
1µ...2m/20m/200m/20A
AC current measuring accuracy:
±(1% + 5 digits)
Bandwidth for AC current measurements:
40Hz...200Hz
Resistance measuring range:
0,1...200/2k/20k/200k/2M/20M/2000MΩ
Resistance measuring accuracy:
±(0,8% + 3 digits)
Capacitance measuring range:
10p...20n/2000n/2µ/20µ/200µF
Capacitance measuring accuracy:
±(2,5% + 20 digits)
Inductance measuring range:
1µ...2m/20m/200m/2H/20H
Inductance measuring accuracy:
±(2,5% + 20 digits)
Frequency measuring range:
1...2k/20k/200k/2M/10MHz
Frequency measuring accuracy:
±(0,5% + 4 digits)
Temperature measuring range:
-40...1000 °C
Temperature measurement accuracy:
±(1% + 4 digits)
Diode test:
1mA, 3V
Transistors' gain (hFE) test:
3 V
Continuity test:
acoustic signal for R<70Ω
Overall dimensions (W x D x H):
97 x 35 x 189 mm
Weight with battery:
400 g
Power supply:
1 battery 9V 6F22, set without battery
Standard equipment:
  • adapter for capacitance and transistors' gain (hFE) measurement
  • test leads
  • drop-like K-type probe with banana clips 4mm TP-09
Optional equipment:
AX-58P soft cover
Conform to the norm:
EN61010 600V CAT IV
Additional information
Gross weight:
0.634 kg