Generator: function; Band: ≤15MHz; LCD TFT 3,5"; Channels: 2

AX-C830

Thermocouple calibrator; V DC: -10m÷75mV; Measuring unit: °C, °F

AX-DG1005AF

Generator: function; Band: ≤5MHz; LCD TFT 3,5"; Channels: 2

AX-C605

Loop calibrator; V DC: 0÷28V; I DC: 0÷22mA; Current source: 0÷22mA

AX-DG100-SOF

Software; Application: AX-DG105; Equipment: RS232 cable, software

AX-LCR41A

LCR meter; LCD 5 digits; 3x/s; 0,0001÷9,999MΩ; R accuracy: ±0,3%

AX-C708

Multimeter calibrator; V DC: 0,01m÷40m/400m/4/40/400V

AX-EL600W

Electronic load; LCD 4,3", with a backlit; 0÷150V; 0.001÷60A

AX-C850

RTD calibrator; R range: 0,01÷400/1500/3200Ω

AX-LCR42A

LCR meter; double LCD (19,999/1999), bargraph, with a backlit

AXIOMET Catalogue

Download Catalogue
(ver. 6)
PDF (12,9 MB)

AX-TI220

Insulation resistance meter; LCD (5000), with a backlit

Product groups: Insulation resistance meters
Related files:
Prices
Product specifications
Type of meter:
insulation resistance meter
Kind of display used:
LCD (5000), with a backlit
Resistance measuring range:
0,1...500/5k/50k/500k/5M/50MΩ
Resistance measuring accuracy:
±(0,3% + 5 digits)
Insulation resistance measuring ranges:
0,05M...0,1M/0,25M/0,5M/1M/10M/100M/2GΩ
Insulation resistance measuring accuracy:
±(1,5% + 5 digits)
AC voltage measuring range:
0,1m...500m/5/50/500/1000V
AC voltage measuring accuracy:
±(0.8% + 4 digits)
Bandwidth for AC voltage measurements:
40Hz...400Hz
DC voltage measuring range:
0,1m...500m/5/50/500/1000V
DC voltage measuring accuracy:
±(0,1% + 2 digits)
AC current measuring range:
0,1µ...500µ/5000µ/50m/500mA
AC current measuring accuracy:
±(0,8% + 4 digits)
DC current measuring range:
0,1µ...500µ/5000µ/50m/500mA
DC current measuring accuracy:
±(0,2% + 2 digits)
True effective value measurement:
True RMS AC+DC
Capacitance measuring range:
0,01n...50n/500n/5µ/50µ/500µ/1000µF
Capacitance measuring accuracy:
±(2% + 10 digits)
Frequency measuring range:
0,001...5/2MHz
Frequency measuring accuracy:
±(0,1% + 4 digits)
Temperature measuring range:
-40...537 °C
Temperature measurement accuracy:
±(1% + 1,5°C)
Temperature measurement resolution:
0.1 °C
Diode test:
0,7mA, 2,5V
Continuity test:
acoustic signal for R<25Ω
Pollution degree:
2
Body dimensions:
200 x 100 x 40 mm
Weight with battery:
560 g
Power supply:
6 batteries 1,5V LR03 (AAA), set without battery
Measuring instrument features:
  • auto and manual ranging
  • automatic power-off
  • wide test voltages selection
  • HOLD function
  • MIN/MAX function
  • overload protection
  • low battery indicator
Standard equipment:
  • test probes
  • 2 crocodile clips
  • case
  • temperature probe
Measurement:
frequency, AC voltage, DC voltage, capacitance, AC current, DC current, resistance, insulation resistance, temperature
Conform to the norm:
EN61010 1000V CAT III
Measuring unit:
°C, °F
Test voltage:
  • 1000VDC (range 1M...2GΩ)
  • 100VDC (range 0,1M...100MΩ)
  • 250VDC (range 0.25M...250MΩ)
  • 500VDC (range 0.5M...500MΩ)
  • 50VDC (range 0,05M...50MΩ)
Additional information